Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 17, 2022, 08:27 AM
  • 01 0046_01 0045A_03172022_013707.mp4

Date
03/17/2022
W/O
941336
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00209
PipeID
P25564
Time
1:27 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10011
Sewer Name
01 HOOPER AVENUE-COMPTON CREEK TRUNK
City
LOS ANGELES
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_941336_TV01255_MAR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
01 0045A
Downstream MH
01 0046
Dir. of Survey
Upstream
Length Surveyed
157.6 ft.
Total Length
157.6 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
3
O&M Quick
3221
O&M Rating
8
Overall Index
3
Overall Quick
Overall Rating
11
Pipe schematic from manhole 01 0045A to 01 0046
MH: 01 0045AMH: 01 0046upstream0 ft. OBZ - Obstacles Other, 20 %of cross sectional area, from 04 to 08 o'clock0 ft. MSA - Survey Abandoned - AT DEBRIS/OBSTACLE. REVERSAL COMPLETE.0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish0 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - DEBRIS38.5 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"41.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"83.8 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"86.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"132.6 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"135.3 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"143.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start155.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start157.6 ft. MWL - Water Level, 5 %of cross sectional area157.6 ft. MGO - General Observation - COCKROACHES IN MH157.6 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK157.6 ft. AMH - Downstream Manhole, Survey Begins - 01 0045A157.6 ft. MWM - Water Mark, 15 %of cross sectional area

Observation photos (6)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    14.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Obstacles Other, 20 %of cross sectional area, from 04 to 08 o'clock

    157.6 ft. - Obstacles Other, 20 %of cross sectional area, from 04 to 08 o'clock

  • Survey Abandoned - AT DEBRIS/OBSTACLE. REVERSAL COMPLETE.

    157.6 ft. - Survey Abandoned - AT DEBRIS/OBSTACLE. REVERSAL COMPLETE.

  • Deposits Settled Other,  15 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES - DEBRIS

    157.6 ft. - Deposits Settled Other, 15 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - DEBRIS

Observations (18)

DistanceCodeObservation
157.6OBZ
14.5CM
22.3TFC
116.5TFC
157.6MSAAT DEBRIS/OBSTACLE. REVERSAL COMPLETE.
73.8TFC
0MWL
2DAGS
0MGOCOCKROACHES IN MH
0MGOCONNECTION AT MH 9 O'CLOCK
157.6DAGS
157.6CM
119.1TFC
0AMH01 0045A
0MWM
25TFC
157.6DSZDEBRIS
71.1TFC

Properties (7)

additional_info
630138031622201
custom_field_three
OBSTACLE/DEBRIS/CRACKS
custom_field_two
2
customer
1
datetime
2022-03-17T01:27:43-07:00
documentation
PRO PIPE
is_lateral_inspection
false