Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 1, 2022, 09:52 AM
  • 01 0063_01 0062_03012022_031212.mp4

Date
03/01/2022
W/O
941336
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00209
PipeID
P00732
Time
1:52 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9888
Sewer Name
01 HOOPER AVENUE-COMPTON CREEK TRUNK
City
FLORENCE-FIRESTONE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_941336_TV01255_MAR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0063
Downstream MH
01 0062
Dir. of Survey
Downstream
Length Surveyed
359.9 ft.
Total Length
359.9 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
3
O&M Quick
4133
O&M Rating
16
Overall Index
3
Overall Quick
Overall Rating
19
Pipe schematic from manhole 01 0063 to 01 0062
MH: 01 0063MH: 01 0062downstream0 ft. MGO - General Observation - COCKROACHES IN MH0 ft. AMH - Upstream Manhole, Survey Begins - 01 00630 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start4.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start63.5 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"66.1 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6"110.9 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"113.8 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"124.7 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"124.7 ft. RMC - Roots Medium Connection, from 07 to 11 o'clock, 20 %, within 8 inches of joint: YES130.9 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"163.9 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"195.5 ft. RMC - Roots Medium Connection, from 07 to 11 o'clock, 15 %, within 8 inches of joint: YES195.5 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"205 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"240.5 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"252.3 ft. RFC - Roots Fine Connection, from 08 to 11 o'clock252.3 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"281.7 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"281.7 ft. RMC - Roots Medium Connection, from 01 to 04 o'clock, 15 %, within 8 inches of joint: YES314.1 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"317.1 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"328.6 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"355.1 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"357.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish357.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish359.9 ft. AMH - Downstream Manhole, Survey Ends - 01 0062

Observation photos (7)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    4.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Roots Medium Connection, from 07 to 11 o'clock, 20 %, within 8 inches of joint: YES

    124.7 ft. - Roots Medium Connection, from 07 to 11 o'clock, 20 %, within 8 inches of joint: YES

  • Roots Medium Connection, from 07 to 11 o'clock, 15 %, within 8 inches of joint: YES

    195.5 ft. - Roots Medium Connection, from 07 to 11 o'clock, 15 %, within 8 inches of joint: YES

  • Roots Fine Connection, from 08 to 11 o'clock

    252.3 ft. - Roots Fine Connection, from 08 to 11 o'clock

  • Roots Medium Connection, from 01 to 04 o'clock, 15 %, within 8 inches of joint: YES

    281.7 ft. - Roots Medium Connection, from 01 to 04 o'clock, 15 %, within 8 inches of joint: YES

Observations (30)

DistanceCodeObservation
205TFA
0MGOCOCKROACHES IN MH
4.8CM
163.9TFA
0AMH01 0063
110.9TFA
252.3RFC
0MWM
357.8DAGS
281.7TFA
195.5RMC
317.1TFA
124.7TFA
314.1TF
281.7RMC
359.9AMH01 0062
66.1TF
0MGOCONNECTION AT MH 3 O'CLOCK
240.5TFA
252.3TFA
357.8CM
63.5TFC
113.8TFA
0MWL
124.7RMC
130.9TFA
2DAGS
328.6TFA
355.1TFA
195.5TFA

Properties (7)

additional_info
630138022822201
custom_field_three
MULTIPLE CRACKS/ROOTS
custom_field_two
2
customer
1
datetime
2022-03-01T01:52:00-08:00
documentation
PRO PIPE
is_lateral_inspection
false