Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 16, 2022, 05:31 AM
  • 01 0058_01 0057_03152022_230056.mp4

Date
03/15/2022
W/O
941336
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00209
PipeID
P00727
Time
10:31 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10010
Sewer Name
01 HOOPER AVENUE-COMPTON CREEK TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_941336_TV01255_MAR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
01 0058
Downstream MH
01 0057
Dir. of Survey
Downstream
Length Surveyed
322.2 ft.
Total Length
322.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
3
O&M Quick
4131
O&M Rating
9
Overall Index
3
Overall Quick
Overall Rating
12
Pipe schematic from manhole 01 0058 to 01 0057
MH: 01 0058MH: 01 0057downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 00580 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MGO - General Observation - COCKROACHES IN MH2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start36.9 ft. MWL - Water Level, 60 %of cross sectional area60.1 ft. MWL - Water Level, 30 %of cross sectional area73.2 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"76.4 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"103.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"106.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"239 ft. MWL - Water Level, 50 %of cross sectional area251.8 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"254.5 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"259.2 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES - DEBRIS301.4 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"303.7 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"320.1 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish320.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish322.2 ft. AMH - Downstream Manhole, Survey Ends - 01 0057322.2 ft. MGO - General Observation - COCKROACHES IN MH322.2 ft. MGO - General Observation - CONNECTION AT MH 3 AND 9 O'CLOCK

Observation photos (4)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MH

    322.2 ft. - General Observation - COCKROACHES IN MH

Observations (24)

DistanceCodeObservation
2DAGS
0AMH01 0058
254.5TFA
0MWM
303.7TFC
60.1MWL
36.9MWL
106.2TFC
301.4TFC
0MWL
322.2AMH01 0057
73.2TFA
2CM
0MGOCONNECTION AT MH 9 O'CLOCK
0MGOCOCKROACHES IN MH
239MWL
320.1CM
322.2MGOCOCKROACHES IN MH
320.1DAGS
103.7TFC
259.2DSZDEBRIS
322.2MGOCONNECTION AT MH 3 AND 9 O'CLOCK
251.8TFA
76.4TFC

Properties (7)

additional_info
630138031522201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-03-15T22:31:36-07:00
documentation
PRO PIPE
is_lateral_inspection
false