Wastewater/Activity/PacpInspection/1.0Mar 17, 2022, 09:59 AM
  • 01 0036B_01 0036A_03172022_030716.mp4

Date
03/17/2022
W/O
941336
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00209
PipeID
P00695
Time
2:59 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10011
Sewer Name
01 HOOPER AVENUE-COMPTON CREEK TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_941336_TV01255_MAR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
27 in.
Upstream MH
01 0036B
Downstream MH
01 0036A
Dir. of Survey
Downstream
Length Surveyed
90.2 ft.
Total Length
90.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 01 0036B to 01 0036A
MH: 01 0036BMH: 01 0036Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 0036B0 ft. MGO - General Observation - COCKROACHES IN MH0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"4.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start5.8 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 6"51.7 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"54.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"88.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish88.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish90.2 ft. MGO - General Observation - COCKROACHES IN MH90.2 ft. AMH - Downstream Manhole, Survey Ends - 01 0036A90.2 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (3)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MH

    90.2 ft. - General Observation - COCKROACHES IN MH

Observations (15)

DistanceCodeObservation
54.5TFC
0AMH01 0036B
90.2MGOCOCKROACHES IN MH
0MGOCOCKROACHES IN MH
5.8TF
90.2AMH01 0036A
51.7TFC
88.1DAGS
4.1CM
3TFC
0MWM
88.1CM
90.2MGOCONNECTION AT MH 3 O'CLOCK
0MWL
2DAGS

Properties (7)

additional_info
630138031622201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-03-17T02:59:02-07:00
documentation
PRO PIPE
is_lateral_inspection
false