- Date
- 02/28/2022
- W/O
- 941336
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00209
- PipeID
- P00743
- Time
- 4:31 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9887
- Sewer Name
- 01 HOOPER AVENUE-COMPTON CREEK TRUNK
- City
- FLORENCE-GRAHAM
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 06
- Purpose
- Routine Assessment
- Project
- RFIR_WO_941336_TV01255_MAR2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 01 0074
- Downstream MH
- 01 0073
- Dir. of Survey
- Downstream
- Length Surveyed
- 319.1 ft.
- Total Length
- 319.1 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 2
- O&M Quick
- 2111
- O&M Rating
- 3
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 6
Pipe schematic from manhole 01 0074 to 01 0073 Observation photos (5)

0 ft. - General Observation - COCKROACHES IN MH

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

27.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

232.1 ft. - Roots Fine Connection, from 08 to 11 o'clock

319.1 ft. - General Observation - COCKROACHES IN MH