Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 1, 2022, 06:32 AM
  • 01 0069_01 0068_02282022_234559.mp4

Date
02/28/2022
W/O
941336
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00209
PipeID
P00738
Time
10:32 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9888
Sewer Name
01 HOOPER AVENUE-COMPTON CREEK TRUNK
City
FLORENCE-GRAHAM
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_941336_TV01255_MAR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0069
Downstream MH
01 0068
Dir. of Survey
Downstream
Length Surveyed
296.2 ft.
Total Length
296.2 ft.
Structural Index
4
Structural Quick
4231
Structural Rating
11
O&M Index
2
O&M Quick
4121
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
18
Pipe schematic from manhole 01 0069 to 01 0068
MH: 01 0069MH: 01 0068downstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 45 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 00692 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start4.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start43.9 ft. FM - Fracture Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES63.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"107.5 ft. RFL - Roots Fine Lateral, from 08 to 11 o'clock107.5 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"144 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"183.1 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"218.9 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"260.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"285.9 ft. FM - Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES293.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish293.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish296.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK296.2 ft. AMH - Downstream Manhole, Survey Ends - 01 0068296.2 ft. MGO - General Observation - COCKROACHES IN MH

Observation photos (6)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    4.8 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

    43.9 ft. - Fracture Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Roots Fine Lateral, from 08 to 11 o'clock

    107.5 ft. - Roots Fine Lateral, from 08 to 11 o'clock

  • Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

    285.9 ft. - Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MH

    296.2 ft. - General Observation - COCKROACHES IN MH

Observations (20)

DistanceCodeObservation
218.9TFA
2DAGS
260.9TFC
293.8CM
63.1TFC
107.5RFL
0MGOCONNECTION AT MH 9 O'CLOCK
107.5TFA
293.8DAGS
285.9FM
0MWL
0MWM
296.2MGOCONNECTION AT MH 9 O'CLOCK
183.1TFA
296.2AMH01 0068
0AMH01 0069
4.8CM
144TFA
43.9FM
296.2MGOCOCKROACHES IN MH

Properties (7)

additional_info
630138022822201
custom_field_three
MULTIPLE CRACKS
custom_field_two
2
customer
1
datetime
2022-02-28T22:32:05-08:00
documentation
PRO PIPE
is_lateral_inspection
false