- Date
- 03/14/2022
- W/O
- 941503
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00742
- PipeID
- P18979
- Time
- 2:16 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K10007
- Sewer Name
- 20 TRUNK "A"
- City
- PALMDALE
- Loc. details
- Main Highway - Suburban/Rural
- Location Code
- B
- Use of Sewer
- Sanitary Sewer
- District
- District 20
- Page No.
- 02
- Purpose
- Routine Assessment
- Project
- RFIR_WO_941503_TV20023_MAR2022
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 24 in.
- Width
- 24 in.
- Upstream MH
- 20 0057
- Downstream MH
- 20 0058
- Dir. of Survey
- Upstream
- Length Surveyed
- 423.1 ft.
- Total Length
- 423.1 ft.
- Structural Index
- 3
- Structural Quick
- 513P
- Structural Rating
- 425
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 427
Pipe schematic from manhole 20 0057 to 20 0058 Observation photos (4)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

4.5 ft. - General Observation - MAG COAT

294.7 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES