Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 11, 2022, 10:26 AM
  • 17 0025_17 0024_4112022_032828.mp4

Date
04/11/2022
W/O
0946947
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00668
PipeID
P13749
Time
3:26 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3061R
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
PASADENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
04
Purpose
Maintenance Related
Project
20220408MDM_DISTRICT_17_MAIN_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
14.5 in.
Upstream MH
17 0025
Downstream MH
17 0024
Dir. of Survey
Downstream
Length Surveyed
394.6 ft.
Total Length
394.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3200
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 17 0025 to 17 0024
MH: 17 0025MH: 17 0024downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:45AM246 ft. RMC - Roots Medium Connection, from 01 to 05 o'clock, 15 %, within 8 inches of joint: NO332.1 ft. RMC - Roots Medium Connection, from 01 to 04 o'clock, 10 %, within 8 inches of joint: NO394.6 ft. AMH - Downstream Manhole, Survey Ends - 4:05AM

Observation photos (2)

  • Roots Medium Connection, from 01 to 05 o'clock, 15 %, within 8 inches of joint: NO

    246 ft. - Roots Medium Connection, from 01 to 05 o'clock, 15 %, within 8 inches of joint: NO

  • Roots Medium Connection, from 01 to 04 o'clock, 10 %, within 8 inches of joint: NO

    332.1 ft. - Roots Medium Connection, from 01 to 04 o'clock, 10 %, within 8 inches of joint: NO

Observations (6)

DistanceCodeObservation
246RMC
0MWL
332.1RMC
394.6AMH4:05AM
0MWM
0AMH3:45AM

Properties (6)

additional_info
ROOT EVALUATION ONLY
customer
LACSD
datetime
2022-04-11T03:26:50-07:00
documentation
MARTIN,REVELES,IGNACIO
is_lateral_inspection
false
lining
CIPP