Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 7, 2022, 07:20 AM
  • 18 0377_18 0376_472022_005430.mp4

Date
04/07/2022
W/O
0946885
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00690
PipeID
P14211
Time
12:20 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3058
Sewer Name
18 NORTH NORWALK TRUNK
City
NORWALK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
25
Purpose
Capital Improvement Program Assesment
Project
20220407MDM_NORTH_NORWALK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
18 0377
Downstream MH
18 0376
Dir. of Survey
Downstream
Length Surveyed
142.9 ft.
Total Length
142.9 ft.
Structural Index
3
Structural Quick
4835
Structural Rating
89
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
89
Pipe schematic from manhole 18 0377 to 18 0376
MH: 18 0377MH: 18 0376downstream0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:55AM0 ft. MWL - Water Level, 10 %of cross sectional area7 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT10.5 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SL15.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL22.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - HAIRLINE22.9 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SL27.1 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL27.1 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL30.7 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL30.7 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL35 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H35 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL40.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped46.4 ft. FC - Fracture Circumferential, from 08 to 01 o'clock, within 8 inches of joint: YES - SL54.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLL58.6 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SL62.6 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SL66.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL70.8 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL74.7 ft. FC - Fracture Circumferential, from 08 to 01 o'clock, within 8 inches of joint: YES - SL74.7 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - H78.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL83 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL87 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - H91.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped102.4 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL110.7 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SL114.4 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES - SL114.5 ft. FC - Fracture Circumferential, from 08 to 02 o'clock, within 8 inches of joint: YES - SL117.9 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SL122.3 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SL126.5 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - SL126.5 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H130.7 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL130.7 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H134.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL139 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - H142.2 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active142.9 ft. AMH - Downstream Manhole, Survey Ends - 1:30AM

Observation photos (2)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

    66.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

    78.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SL

Observations (42)

DistanceCodeObservation
15.1FMSL
110.7FCSL
74.7FCSL
0MGOConn. @ Mh, 9 O' Clock. Active
46.4FCSL
114.4FLSL
22.9FMHAIRLINE
91.5TFCCapped
142.9AMH1:30AM
78.6FMSL
35FCH
10.5FCSL
102.4FCSL
130.7FCSL
30.7FCSL
74.7FCH
83FMSL
117.9FCSL
58.6FLSL
142.2MGOConn. @ Mh, 3 O' Clock. Active
134.6FMSL
27.1FCSL
130.7FCH
54.3FMSLL
126.5FLSL
0MWM
0AMH12:55AM
0MWL
66.4FMSL
40.1TFCCapped
70.8FCSL
87FMH
22.9FLSL
7FCSLIGHT
27.1FCSL
122.3FCSL
114.5FCSL
35FCSL
139FLH
30.7FCSL
62.6FCSL
126.5FCH

Properties (6)

custom_field_three
SLIGHT FRACTURES AT JOINTS
custom_field_two
2
customer
LACSD
datetime
2022-04-07T00:20:24-07:00
documentation
MARTIN,REVELES,IGNACIO
is_lateral_inspection
false