Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 3, 2022, 03:16 PM
  • 05 0776_05 2231_03032022_082410.mp4

Date
03/03/2022
W/O
941467
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00553
PipeID
P06004
Time
7:16 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9911
Sewer Name
05 MANCHESTER-VERMONT DIVERSION EXTENSION TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
WO_941467_TV05272_MAR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 2231
Downstream MH
05 0776
Dir. of Survey
Upstream
Length Surveyed
162.8 ft.
Total Length
162.8 ft.
Structural Index
4
Structural Quick
4E00
Structural Rating
128
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
128
Pipe schematic from manhole 05 2231 to 05 0776
MH: 05 2231MH: 05 0776upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 07760 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish158.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start162.8 ft. MWL - Water Level, 10 %of cross sectional area162.8 ft. AMH - Downstream Manhole, Survey Begins - 05 2231162.8 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK162.8 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK162.8 ft. MWM - Water Mark, 10 %of cross sectional area

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
162.8AMH05 0776
0MWL
162.8FM
0AMH05 2231
0MGOCONNECTION AT THE MH 3 OC'LOCK
0MGOCONNECTION AT THE MH 9 OC'LOCK
0MWM
4.1FM

Properties (7)

additional_info
630074030322061
custom_field_three
MULTIPLE FRACTURES
custom_field_two
1
customer
1
datetime
2022-03-03T07:16:57-08:00
documentation
PROPIPE
is_lateral_inspection
false