Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 4, 2022, 09:32 AM
  • 05 1094_05 1093_03042022_025101.mp4

Date
03/04/2022
W/O
941470
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00488
PipeID
P06328
Time
1:32 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9787
Sewer Name
05 MONETA EXTENSION TRUNK, SECTION 1
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
18
Purpose
Routine Assessment
Project
RFIR_WO_941470_TV05328_MAR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
15 in.
Upstream MH
05 1094
Downstream MH
05 1093
Dir. of Survey
Downstream
Length Surveyed
322.4 ft.
Total Length
322.4 ft.
Structural Index
3
Structural Quick
5344
Structural Rating
223
O&M Index
2
O&M Quick
412L
O&M Rating
134
Overall Index
3
Overall Quick
Overall Rating
357
Pipe schematic from manhole 05 1094 to 05 1093
MH: 05 1094MH: 05 1093downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 10940 ft. MWM - Water Mark, 50 %of cross sectional area3.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start4.2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start24.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"27.4 ft. FM - Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES67 ft. FM - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES111.9 ft. B - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES125.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"125.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 01 to 11 o'clock, , within 8 inches of joint: YES129.6 ft. FM - Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES216.8 ft. BSV - Broken Soil Visible, from 10 to 04 o'clock, within 8 inches of joint: YES226.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"231.1 ft. FS - Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES280.5 ft. FM - Fracture Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES311.7 ft. B - Broken, from 01 to 05 o'clock, within 8 inches of joint: YES321.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish321.5 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish322.4 ft. AMH - Downstream Manhole, Survey Ends - 05 1093

Observation photos (11)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    3.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    4.2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

    27.4 ft. - Fracture Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

    67 ft. - Fracture Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES

  • Broken, from 08 to 04 o'clock, within 8 inches of joint: YES

    111.9 ft. - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 01 to 11 o'clock,  , within 8 inches of joint: YES

    125.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 01 to 11 o'clock, , within 8 inches of joint: YES

  • Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

    129.6 ft. - Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

  • Broken Soil Visible, from 10 to 04 o'clock, within 8 inches of joint: YES

    216.8 ft. - Broken Soil Visible, from 10 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES

    231.1 ft. - Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES

    280.5 ft. - Fracture Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES

  • Broken, from 01 to 05 o'clock, within 8 inches of joint: YES

    311.7 ft. - Broken, from 01 to 05 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
226.8TF
231.1FS
4.2CM
27.4FM
280.5FM
111.9B
0MWL
0AMH05 1094
129.6FM
216.8BSV
125.3TF
3.4DAGS
125.3DAGS
0MWM
67FM
321.5DAGS
311.7B
321.5CM
24.3TF
322.4AMH05 1093

Properties (7)

additional_info
630074030322202
custom_field_three
BROKEN, SEVERE FRACTURES
custom_field_two
1
customer
1
datetime
2022-03-04T01:32:27-08:00
documentation
PROPIPE
is_lateral_inspection
false