Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 17, 2022, 11:25 AM
  • 17 0060_17 0059_02172022_034235.mp4

Date
02/17/2022
W/O
936263
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00668
PipeID
P13779
Time
3:25 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9874
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
ALTADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
04
Purpose
Routine Assessment
Project
WO_936263_TV17011_FEB2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
17 0060
Downstream MH
17 0059
Dir. of Survey
Downstream
Length Surveyed
436.6 ft.
Total Length
436.6 ft.
Structural Index
3
Structural Quick
3P2P
Structural Rating
430
O&M Index
2
O&M Quick
2P11
O&M Rating
173
Overall Index
2
Overall Quick
Overall Rating
603
Pipe schematic from manhole 17 0060 to 17 0059
MH: 17 0060MH: 17 0059downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 17 00602 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.5 ft. MGO - General Observation - 60% MAG COAT30.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"107.1 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES109.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN296 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN434 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish434.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish434.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish436.6 ft. AMH - Downstream Manhole, Survey Ends - 17 0059436.6 ft. MGO - General Observation - ROACHES

Observation photos (5)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - 60% MAG COAT

    2.5 ft. - General Observation - 60% MAG COAT

  • Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN

    109.9 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN

  • General Observation - ROACHES

    436.6 ft. - General Observation - ROACHES

Observations (16)

DistanceCodeObservation
0MWL
109.9TFOPEN
2.5SAP
434.2SAP
107.1RFJ
434.2DAGS
0MWM
2.5MGO60% MAG COAT
30.8TFA
296TFOPEN
0AMH17 0060
434SSS
436.6AMH17 0059
2SSS
436.6MGOROACHES
2DAGS

Properties (7)

additional_info
630074021622202
custom_field_three
PROJECTING AGGREGATE
custom_field_two
3
customer
1
datetime
2022-02-17T03:25:07-08:00
documentation
PRO PIPE
is_lateral_inspection
false