- Date
- 03/02/2022
- W/O
- 941501
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00699
- PipeID
- P14245
- Time
- 2:08 AM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9893
- Sewer Name
- 18 SANTA FE STREET RELIEF TRUNK
- City
- WHITTIER
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- RFIR_WO_941501_TV18173_MAR2022
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 18 in.
- Width
- 18 in.
- Upstream MH
- 18 0410
- Downstream MH
- 18 0409
- Dir. of Survey
- Downstream
- Length Surveyed
- 128.9 ft.
- Total Length
- 128.9 ft.
- Structural Index
- 2
- Structural Quick
- 3D2D
- Structural Rating
- 127
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 127
Pipe schematic from manhole 18 0410 to 18 0409 Observation photos (4)

2.6 ft. - General Observation - MAG COAT

2.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

107.3 ft. - Crack Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES