- Date
- 03/03/2022
- W/O
- 941501
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00699
- PipeID
- P14236
- Time
- 1:34 AM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9800
- Sewer Name
- 18 SANTA FE STREET RELIEF TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 20
- Purpose
- Routine Assessment
- Project
- RFIR_WO_941501_TV18173_MAR2022
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 18 0401A
- Downstream MH
- 18 0401
- Dir. of Survey
- Downstream
- Length Surveyed
- 78.2 ft.
- Total Length
- 78.2 ft.
- Structural Index
- 3
- Structural Quick
- 3B2B
- Structural Rating
- 75
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 75
Pipe schematic from manhole 18 0401A to 18 0401 Observation photos (4)

2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

15.1 ft. - General Observation - MAG COAT

55.5 ft. - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: YES, 8"