Wastewater/Activity/PacpInspection/1.0Feb 18, 2022, 08:13 AM
  • 29 0338_29 0337_02182022_014041.mp4

Date
02/18/2022
W/O
941464
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01017
PipeID
P24357
Time
12:13 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9741
Sewer Name
29 PACIFIC COAST HIGHWAY SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_941464_TV29105_MAR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0338
Downstream MH
29 0337
Dir. of Survey
Downstream
Length Surveyed
375 ft.
Total Length
375 ft.
Structural Index
3
Structural Quick
3O00
Structural Rating
243
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
243
Pipe schematic from manhole 29 0338 to 29 0337
MH: 29 0338MH: 29 0337downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 03380 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK2 ft. MGO - General Observation - PIPE IS NRCP2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start36.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - DEBRIS45.5 ft. FS - Fracture Spiral, from 12 to 03 o'clock, within 8 inches of joint: YES91.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - DEBRIS111.9 ft. CM - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES167.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - DEBRIS177.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - DEBRIS180.9 ft. CM - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES193.9 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES211 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 8"240.8 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - DEBRIS250.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"313.7 ft. FS - Fracture Spiral, from 07 to 11 o'clock, within 8 inches of joint: YES329.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES333.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"335.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - DEBRIS358.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - DEBRIS374.9 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK374.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish375 ft. AMH - Downstream Manhole, Survey Ends - 29 0337

Observation photos (11)

  • General Observation - PIPE IS NRCP

    2 ft. - General Observation - PIPE IS NRCP

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Spiral, from 12 to 03 o'clock, within 8 inches of joint: YES

    45.5 ft. - Fracture Spiral, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - DEBRIS

    91.5 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - DEBRIS

  • Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

    111.9 ft. - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

    180.9 ft. - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    193.9 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 8"

    211 ft. - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 8"

  • Fracture Spiral, from 07 to 11 o'clock, within 8 inches of joint: YES

    313.7 ft. - Fracture Spiral, from 07 to 11 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    329.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    333.3 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"

Observations (25)

DistanceCodeObservation
0MWL
2MGOPIPE IS NRCP
240.8TBDEBRIS
36.5TFDEBRIS
211TB
333.3TB
329.2CM
0AMH29 0338
180.9CM
91.5TBDEBRIS
250.8TF
177.2TFDEBRIS
374.9MGOCONNECTION AT THE MH 9 OC'LOCK
313.7FS
0MWM
193.9FL
374.9SAV
45.5FS
167.1TFDEBRIS
335.3TFDEBRIS
0MGOCONNECTION AT THE MH 9 OC'LOCK
358.2TFDEBRIS
2.1SAV
111.9CM
375AMH29 0337

Properties (7)

additional_info
630074021722202
custom_field_three
FRACTURES, CRACKS, AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2022-02-18T00:13:26-08:00
documentation
PRO PIPE
is_lateral_inspection
false