Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 1, 2022, 08:12 AM
  • 18 1044_18 1043_03012022_012825.mp4

Date
03/01/2022
W/O
941485
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00678
PipeID
P14898
Time
12:12 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9749
Sewer Name
18 LA HABRA HEIGHTS TRUNK, SECTION 2A
City
WHIITIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_941485_TV18015_MAR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
18 1043
Downstream MH
18 1044
Dir. of Survey
Upstream
Length Surveyed
263.7 ft.
Total Length
263.7 ft.
Structural Index
3
Structural Quick
513I
Structural Rating
160
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
160
Pipe schematic from manhole 18 1043 to 18 1044
MH: 18 1043MH: 18 1044upstream0 ft. MGO - General Observation - GIS CALLS FOR 262'0 ft. AMH - Upstream Manhole, Survey Ends - 18 10440 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK44.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"104.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"149.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"225.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"227.7 ft. B - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES252.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start254.9 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES255.5 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES263.7 ft. MWL - Water Level, 10 %of cross sectional area263.7 ft. AMH - Downstream Manhole, Survey Begins - 18 1043263.7 ft. MWM - Water Mark, 25 %of cross sectional area263.7 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK

Observation photos (4)

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    8.2 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    8.8 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    11.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 08 to 04 o'clock, within 8 inches of joint: YES

    36 ft. - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
0MWL
263.7MGOGIS CALLS FOR 262'
11.5CM
219.6TF
158.8TF
263.7AMH18 1044
263.7CM
8.2FL
8.8CL
36B
0AMH18 1043
113.8TFA
38TF
263.7MGOCONNECTION AT THE MH 9 OC'LOCK
0MWM
0MGOCONNECTION AT THE MH 9 OC'LOCK

Properties (7)

additional_info
630074022822201
custom_field_three
BROKEN PIPE
custom_field_two
2
customer
1
datetime
2022-03-01T00:12:00-08:00
documentation
PRO PIPE
is_lateral_inspection
false