- Date
- 03/07/2022
- W/O
- 941506
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00711
- PipeID
- P14974
- Time
- 2:57 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9913
- Sewer Name
- 18 STAGE ROAD JUNCTION TRUNK
- City
- SANTA FE SPRINGS
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 31
- Purpose
- Routine Assessment
- Project
- RFIR_WO941506_TV18190_MAR2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 10 in.
- Width
- 10 in.
- Upstream MH
- 18 1121
- Downstream MH
- 18 1120
- Dir. of Survey
- Downstream
- Length Surveyed
- 270.4 ft.
- Total Length
- 270.4 ft.
- Structural Index
- 3
- Structural Quick
- 433I
- Structural Rating
- 159
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 159
Pipe schematic from manhole 18 1121 to 18 1120 Observation photos (4)

9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

16.5 ft. - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"

24.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

117 ft. - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: NO, 6"