Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 2, 2022, 06:11 AM
  • 18 1000_18 0999_03012022_232234.mp4

Date
03/01/2022
W/O
941296
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00677
PipeID
P14854
Time
10:11 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9892
Sewer Name
18 LA HABRA HEIGHTS TRUNK, SECTION 1
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
WO_941296_TV18158_MAR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
18 1000
Downstream MH
18 0999
Dir. of Survey
Downstream
Length Surveyed
53.9 ft.
Total Length
53.9 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 18 1000 to 18 0999
MH: 18 1000MH: 18 0999downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 10000 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. MWM - Water Mark, 30 %of cross sectional area5.1 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES53.9 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK53.9 ft. AMH - Downstream Manhole, Survey Ends - 18 0999

Observation photos (1)

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    5.1 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
0AMH18 1000
0MWL
5.1CM
0MGOCONNECTION AT THE MH 9 OC'LOCK
53.9MGOCONNECTION AT THE MH 9 OC'LOCK
53.9AMH18 0999
0MWM

Properties (7)

additional_info
630074030122202
custom_field_three
LIGHT CRACKS
custom_field_two
4
customer
1
datetime
2022-03-01T22:11:00-08:00
documentation
PRO PIPE
is_lateral_inspection
false