Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 15, 2022, 09:27 AM
  • J 0183_J 0182_02152022_020117.mp4

Date
02/15/2022
W/O
936261
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00055
PipeID
P11422
Time
1:27 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9736
Sewer Name
J JOINT OUTFALL J - UNIT 1C
City
SAN PEDRO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
47A
Purpose
Routine Assessment
Project
WO_936261_TV05161_FEB2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
J 0183
Downstream MH
J 0182
Dir. of Survey
Downstream
Length Surveyed
426.7 ft.
Total Length
426.7 ft.
Structural Index
2
Structural Quick
2P00
Structural Rating
170
O&M Index
2
O&M Quick
412M
O&M Rating
146
Overall Index
2
Overall Quick
Overall Rating
316
Pipe schematic from manhole J 0183 to J 0182
MH: J 0183MH: J 0182downstream0 ft. AMH - Upstream Manhole, Survey Begins - J 01830 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 40 %of cross sectional area2 ft. MGO - General Observation - MAG COAT2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start72.2 ft. DSC - Deposits Settled Compacted, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start426.7 ft. AMH - Downstream Manhole, Survey Ends - J 0182426.7 ft. DSC - Deposits Settled Compacted, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish426.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish426.7 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK (ACTIVE STATUS UNKNOWN, NO DIRECT VIEW).

Observation photos (3)

  • General Observation - MAG COAT

    2 ft. - General Observation - MAG COAT

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Settled Compacted,  10 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: YES, Start

    72.2 ft. - Deposits Settled Compacted, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0AMHJ 0183
2MGOMAG COAT
426.7AMHJ 0182
0MWM
426.7DSC
72.2DSC
2SSS
0MWL
426.7SSS
426.7MGOCONNECTION AT THE MH 9 OC'LOCK (ACTIVE STATUS UNKNOWN, NO DIRECT VIEW).

Properties (7)

additional_info
630074021422201
custom_field_three
SPALLING, MAG COAT
custom_field_two
3
customer
1
datetime
2022-02-15T01:27:24-08:00
documentation
PRO PIPE
is_lateral_inspection
false