Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 14, 2022, 10:53 AM
  • J 0166_J 0165_02142022_030903.mp4

Date
02/14/2022
W/O
936261
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00055
PipeID
P11409
Time
2:53 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9735
Sewer Name
J JOINT OUTFALL J - UNIT 1C
City
RANCHO PALOS VERDES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
44
Purpose
Routine Assessment
Project
WO_936261_TV05161_FEB2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
J 0166
Downstream MH
J 0165
Dir. of Survey
Downstream
Length Surveyed
505.6 ft.
Total Length
505.6 ft.
Structural Index
2
Structural Quick
2S00
Structural Rating
202
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
202
Pipe schematic from manhole J 0166 to J 0165
MH: J 0166MH: J 0165downstream0 ft. AMH - Upstream Manhole, Survey Begins - J 01660 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.2 ft. MGO - General Observation - MAG COAT475.2 ft. TBA - Tap Break-In Active, at 03 o'clock, -, within 8 inches of joint: NO, 18"489.5 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 10"505.6 ft. AMH - Downstream Manhole, Survey Ends - J 0165505.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (3)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAG COAT

    2.2 ft. - General Observation - MAG COAT

  • Tap Break-In Active, at 03 o'clock, -, within 8 inches of joint: NO, 18"

    475.2 ft. - Tap Break-In Active, at 03 o'clock, -, within 8 inches of joint: NO, 18"

Observations (9)

DistanceCodeObservation
505.6AMHJ 0165
0AMHJ 0166
475.2TBA
2.2SSS
0MWM
505.6SSS
0MWL
2.2MGOMAG COAT
489.5TBA

Properties (7)

additional_info
630074021422001
custom_field_three
SPALLING, MAG COAT
custom_field_two
3
customer
1
datetime
2022-02-14T02:53:19-08:00
documentation
PRO PIPE
is_lateral_inspection
false