- Date
- 02/14/2022
- W/O
- 936261
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00055
- PipeID
- P11409
- Time
- 2:53 AM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9735
- Sewer Name
- J JOINT OUTFALL J - UNIT 1C
- City
- RANCHO PALOS VERDES
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 44
- Purpose
- Routine Assessment
- Project
- WO_936261_TV05161_FEB2022
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- J 0166
- Downstream MH
- J 0165
- Dir. of Survey
- Downstream
- Length Surveyed
- 505.6 ft.
- Total Length
- 505.6 ft.
- Structural Index
- 2
- Structural Quick
- 2S00
- Structural Rating
- 202
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 202
Pipe schematic from manhole J 0166 to J 0165 Observation photos (3)

2.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.2 ft. - General Observation - MAG COAT

475.2 ft. - Tap Break-In Active, at 03 o'clock, -, within 8 inches of joint: NO, 18"