Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 11, 2022, 10:56 AM
  • J 0164_J 0163_02112022_031321.mp4

Date
02/11/2022
W/O
936261
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00055
PipeID
P11407
Time
2:56 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9734
Sewer Name
J JOINT OUTFALL J - UNIT 1C
City
RANCHO PALOS VERDES
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
44
Purpose
Routine Assessment
Project
WO_936261_TV05161_FEB2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
J 0164
Downstream MH
J 0163
Dir. of Survey
Downstream
Length Surveyed
654.8 ft.
Total Length
654.8 ft.
Structural Index
2
Structural Quick
2B00
Structural Rating
26
O&M Index
2
O&M Quick
2B00
O&M Rating
26
Overall Index
2
Overall Quick
Overall Rating
52
Pipe schematic from manhole J 0164 to J 0163
MH: J 0164MH: J 0163downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - J 01640 ft. MWM - Water Mark, 30 %of cross sectional area2.1 ft. MGO - General Observation - MAG COAT2.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start66 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish111.5 ft. DSC - Deposits Settled Compacted, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start176.7 ft. DSC - Deposits Settled Compacted, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish654.8 ft. AMH - Downstream Manhole, Survey Ends - J 0163654.8 ft. MGO - General Observation - ACTIVE CONNECTION AT THE MH 9 O'CLOCK

Observation photos (3)

  • General Observation - MAG COAT

    2.1 ft. - General Observation - MAG COAT

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Settled Compacted,  10 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: YES, Start

    111.5 ft. - Deposits Settled Compacted, 10 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
2.6SSS
66SSS
0MWL
176.7DSC
111.5DSC
2.1MGOMAG COAT
0AMHJ 0164
0MWM
654.8AMHJ 0163
654.8MGOACTIVE CONNECTION AT THE MH 9 O'CLOCK

Properties (7)

additional_info
630074021022202
custom_field_three
MAG COAT, SPALLING
custom_field_two
4
customer
1
datetime
2022-02-11T02:56:25-08:00
documentation
PRO PIPE
is_lateral_inspection
false