Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 9, 2022, 10:20 AM
  • 32 1237_32 1236_03092022_033649.mp4

Date
03/09/2022
W/O
941332
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00832
PipeID
P19706
Time
2:20 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K10002
Sewer Name
32 BOUQUET CANYON TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
07
Purpose
Routine Assessment
Project
WO_941332_TV32007_MAR2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
32 1236
Downstream MH
32 1237
Dir. of Survey
Upstream
Length Surveyed
400.3 ft.
Total Length
400.3 ft.
Structural Index
3
Structural Quick
3O2O
Structural Rating
392
O&M Index
2
O&M Quick
2O00
O&M Rating
158
Overall Index
2
Overall Quick
Overall Rating
550
Pipe schematic from manhole 32 1236 to 32 1237
MH: 32 1236MH: 32 1237upstream0 ft. MGO - General Observation - DATA STATED NRCP. MATERIAL IS VCP.0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. AMH - Upstream Manhole, Survey Ends - 32 12371.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish1.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish22.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"97.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"177.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"251.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"325.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"398.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start398.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start398.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start400.3 ft. AMH - Downstream Manhole, Survey Begins - 32 1236400.3 ft. MWL - Water Level, 5 %of cross sectional area400.3 ft. MWM - Water Mark, 10 %of cross sectional area

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
74.9TFC
400.3MGODATA STATED NRCP. MATERIAL IS VCP.
398.7DAGS
222.9TFC
148.6TFC
302.5TFC
398SSS
2CM
0AMH32 1236
0MWL
377.4TFC
2DAGS
0MWM
2SSS
400.3MGOCONN @ MH 9 O'CLOCK/ACTIVE
398.7CM
400.3AMH32 1237

Properties (7)

additional_info
630138030822202
custom_field_three
SPALLING/CRACKS
custom_field_two
3
customer
1
datetime
2022-03-09T02:20:21-08:00
documentation
PRO PIPE
is_lateral_inspection
false