Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 23, 2022, 10:14 AM
  • E 0191_01 0423_02232022_032204.mp4

Date
02/23/2022
W/O
941344
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00208
PipeID
P02157
Time
2:14 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9880
Sewer Name
01 HOLMES-WILLOWBROOK TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_941344_TV01248_MAR2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
15 in.
Upstream MH
01 0423
Downstream MH
E 0191
Dir. of Survey
Upstream
Length Surveyed
96.1 ft.
Total Length
96.1 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 01 0423 to E 0191
MH: 01 0423MH: E 0191upstream0 ft. AMH - Upstream Manhole, Survey Ends - E 01911.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1.6 ft. MGO - General Observation - STOP LOG AT MOUTH OF PIPE.1.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish90 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start90 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start94.1 ft. MGO - General Observation - MAG COAT96.1 ft. MGO - General Observation - COCKROACHES IN MH96.1 ft. MWL - Water Level, 5 %of cross sectional area96.1 ft. MWM - Water Mark, 10 %of cross sectional area96.1 ft. AMH - Downstream Manhole, Survey Begins - 01 042396.1 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (5)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • General Observation - MAG COAT

    2 ft. - General Observation - MAG COAT

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - STOP LOG AT MOUTH OF PIPE.

    94.5 ft. - General Observation - STOP LOG AT MOUTH OF PIPE.

Observations (12)

DistanceCodeObservation
96.1AMHE 0191
0MGOCOCKROACHES IN MH
0MWL
0MWM
6.1SAP
94.5SSS
94.5MGOSTOP LOG AT MOUTH OF PIPE.
0AMH01 0423
94.5SAP
0MGOCONNECTION AT MH 9 O'CLOCK
6.1SSS
2MGOMAG COAT

Properties (7)

additional_info
630138022222201
custom_field_three
SPALLING/PROJECTING AGGREGATE
custom_field_two
2
customer
1
datetime
2022-02-23T02:14:20-08:00
documentation
PRO PIPE
is_lateral_inspection
false