Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 3, 2022, 08:27 AM
  • 18 0404_18 0403_03032022_014217.mp4

Date
03/03/2022
W/O
941330
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00699
PipeID
P14239
Time
12:27 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9799
Sewer Name
18 SANTA FE STREET RELIEF TRUNK
City
WHITTIER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_941330_TV18189_MAR2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
18 0404
Downstream MH
18 0403
Dir. of Survey
Downstream
Length Surveyed
417.5 ft.
Total Length
417.5 ft.
Structural Index
3
Structural Quick
3P2P
Structural Rating
420
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
423
Pipe schematic from manhole 18 0404 to 18 0403
MH: 18 0404MH: 18 0403downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 04040 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. MGO - General Observation - MAG COAT2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start105.9 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 8"164.8 ft. RFB - Roots Fine Barrell, at 12 o'clock166.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: NO171 ft. RPP - Repair Patch, from 12 to 12 o'clock, within 8 inches of joint: YES - .174.6 ft. RFJ - Roots Fine Joint, from 11 to 12 o'clock, within 8 inches of joint: YES314.3 ft. FS - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES417.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish417.5 ft. AMH - Downstream Manhole, Survey Ends - 18 0403417.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (8)

  • General Observation - MAG COAT

    2 ft. - General Observation - MAG COAT

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Barrell, at 12 o'clock

    164.8 ft. - Roots Fine Barrell, at 12 o'clock

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: NO

    166.1 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: NO

  • Repair Patch, from 12 to 12 o'clock, within 8 inches of joint: YES - .

    171 ft. - Repair Patch, from 12 to 12 o'clock, within 8 inches of joint: YES - .

  • Roots Fine Joint, from 11 to 12 o'clock, within 8 inches of joint: YES

    174.6 ft. - Roots Fine Joint, from 11 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES

    314.3 ft. - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
314.3FS
417.5SAV
2MGOMAG COAT
171RPP.
0AMH18 0404
2SAV
164.8RFB
417.5AMH18 0403
0MWM
166.1CL
105.9TF
0MWL
174.6RFJ
417.5SSS
2SSS

Properties (7)

additional_info
63007403022201
custom_field_three
MAG COAT. AGGREGATE VISIBLE, SPALLING
custom_field_two
3
customer
1
datetime
2022-03-03T00:27:04-08:00
documentation
PRO PIPE
is_lateral_inspection
false