Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 18, 2022, 08:35 PM
  • 05 0130_05 0129_01182022_125315.mp4

Date
01/18/2022
W/O
926973
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00431
PipeID
P05420
Time
12:35 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9707
Sewer Name
05 DISTRICT #5 MAIN TRUNK
City
HAWTHRONE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_926973_TV05147_DEC2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Width
42 in.
Upstream MH
05 0129
Downstream MH
05 0130
Dir. of Survey
Upstream
Length Surveyed
242.1 ft.
Total Length
242.1 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 05 0129 to 05 0130
MH: 05 0129MH: 05 0130upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 01300 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK2.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish139.5 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 8"239.1 ft. MGO - General Observation - MAG COAT239.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start239.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start242.1 ft. AMH - Downstream Manhole, Survey Begins - 05 0129242.1 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK242.1 ft. MWL - Water Level, 15 %of cross sectional area242.1 ft. MWM - Water Mark, 15 %of cross sectional area

Observation photos (3)

  • General Observation - MAG COAT

    3 ft. - General Observation - MAG COAT

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
3MGOMAG COAT
242.1AMH05 0130
3SSS
239.5SAV
0AMH05 0129
242.1MGOCONNECTION AT MH 3 O'CLOCK
242.1MGOCONNECTION AT MH 9 O'CLOCK
102.6TF
239.5SSS
0MGOCONNECTION AT MH 9 O'CLOCK
0MWL
3SAV
0MWM

Properties (6)

custom_field_three
AGGREGATE VISIBLE, SPALLING
custom_field_two
3
customer
1
datetime
2022-01-18T12:35:39-08:00
documentation
PROPIPE
is_lateral_inspection
false