Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 2, 2022, 09:26 AM
  • 08 0058_08 0057_02022022_014251.mp4

Date
02/02/2022
W/O
931501
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00016
PipeID
P00060
Time
1:26 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9722
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_931501_TV08116_JAN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
08 0058
Downstream MH
08 0057
Dir. of Survey
Downstream
Length Surveyed
287.1 ft.
Total Length
287.1 ft.
Structural Index
3
Structural Quick
3K2K
Structural Rating
293
O&M Index
1
O&M Quick
3115
O&M Rating
8
Overall Index
2
Overall Quick
Overall Rating
301
Pipe schematic from manhole 08 0058 to 08 0057
MH: 08 0058MH: 08 0057downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 00580 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/OPEN0 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.5 ft. CM - Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES16.3 ft. CM - Crack Multiple, from 03 to 06 o'clock, within 8 inches of joint: YES28.3 ft. CS - Crack Spiral, from 01 to 03 o'clock, within 8 inches of joint: YES29.6 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN90.5 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN151.2 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"206.2 ft. RFJ - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES210.9 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN244.5 ft. RMC - Roots Medium Connection, at 12 o'clock, 10 %, within 8 inches of joint: NO244.5 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6" - 5% ROOTS245.2 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start263.8 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish285 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish287 ft. MGO - General Observation - ROACHES @ MH287.1 ft. AMH - Downstream Manhole, Survey Ends - 08 0057287.1 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/CAPPED287.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish287.1 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE

Observation photos (8)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

    2.5 ft. - Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 03 to 06 o'clock, within 8 inches of joint: YES

    16.3 ft. - Crack Multiple, from 03 to 06 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 01 to 03 o'clock, within 8 inches of joint: YES

    28.3 ft. - Crack Spiral, from 01 to 03 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES

    206.2 ft. - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YES

  • Roots Medium Connection, at 12 o'clock, 10 %, within 8 inches of joint: NO

    244.5 ft. - Roots Medium Connection, at 12 o'clock, 10 %, within 8 inches of joint: NO

  • Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6" - 5% ROOTS

    244.5 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6" - 5% ROOTS

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    245.2 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (24)

DistanceCodeObservation
287.1AMH08 0057
287MGOROACHES @ MH
2SSS
287.1MGOCONN @ MH 3 O'CLOCK/CAPPED
244.5RMC
151.2TFC
287.1CM
210.9TFOPEN
0AMH08 0058
28.3CS
0MWL
206.2RFJ
2.5CM
285SSS
90.5TFOPEN
244.5TBA5% ROOTS
29.6TFOPEN
0MGOCONN @ MH 9 O'CLOCK/OPEN
0MWM
263.8RFJ
2CM
245.2RFJ
16.3CM
287.1MGOCONN @ MH 9 O'CLOCK/ACTIVE

Properties (7)

additional_info
630074020122201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-02-02T01:26:47-08:00
documentation
PRO PIPE
is_lateral_inspection
false