Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 3, 2022, 06:40 AM
  • 08 0047_08 0046_02022022_225644.mp4

Date
02/02/2022
W/O
931501
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00016
PipeID
P00049
Time
10:40 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9723
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_931501_TV08116_JAN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
21 in.
Upstream MH
08 0046
Downstream MH
08 0047
Dir. of Survey
Upstream
Length Surveyed
309.6 ft.
Total Length
309.6 ft.
Structural Index
2
Structural Quick
3J2K
Structural Rating
284
O&M Index
2
O&M Quick
2J00
O&M Rating
114
Overall Index
2
Overall Quick
Overall Rating
398
Pipe schematic from manhole 08 0046 to 08 0047
MH: 08 0046MH: 08 0047upstream0 ft. AMH - Upstream Manhole, Survey Ends - 08 00470.6 ft. MGO - General Observation - ROACHES @ MH2 ft. DSC - Deposits Settled Compacted, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish48.6 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - 50% GREASE-LATERAL/OPEN90.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN99.4 ft. TFD - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: YES, 4", 6" - 60% GREASE-LATERAL/OPEN150.3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 4", 6"198.3 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - OPEN249.3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"271.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start280.3 ft. DSC - Deposits Settled Compacted, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start301.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"307.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start309.6 ft. MWL - Water Level, 20 %of cross sectional area309.6 ft. MGO - General Observation - ROACHES @ MH309.6 ft. AMH - Downstream Manhole, Survey Begins - 08 0046309.6 ft. MWM - Water Mark, 25 %of cross sectional area

Observation photos (3)

  • Deposits Settled Compacted,  5 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: YES, Start

    29.3 ft. - Deposits Settled Compacted, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    38.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN

    219.1 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN

Observations (19)

DistanceCodeObservation
29.3DSC
0MWL
60.3TFC
2SSS
0MGOROACHES @ MH
219.1TFOPEN
307.6DSC
0AMH08 0046
111.3TFOPEN
8.5TFC
307.6CM
159.3TFC
309.6AMH08 0047
38.2CM
309MGOROACHES @ MH
261TF50% GREASE-LATERAL/OPEN
210.2TFD60% GREASE-LATERAL/OPEN
0MWM
307SSS

Properties (7)

additional_info
630074020222201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-02-02T22:40:32-08:00
documentation
PRO PIPE
is_lateral_inspection
false