Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 25, 2022, 10:44 AM
  • 08 0079_08 0679_01252022_030440.mp4

Date
01/25/2022
W/O
931501
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00016
PipeID
P24648
Time
2:44 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9712
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
RFIR_WO_931501_TV08116_JAN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
08 0079
Downstream MH
08 0679
Dir. of Survey
Downstream
Length Surveyed
377.2 ft.
Total Length
377.2 ft.
Structural Index
2
Structural Quick
3G2N
Structural Rating
269
O&M Index
2
O&M Quick
2N1C
O&M Rating
169
Overall Index
2
Overall Quick
Overall Rating
438
Pipe schematic from manhole 08 0079 to 08 0679
MH: 08 0079MH: 08 0679downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 00790 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start49.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"100.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"149.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN194 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish197 ft. RFJ - Roots Fine Joint, from 09 to 10 o'clock, within 8 inches of joint: YESR201.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"212 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES221.6 ft. CS - Crack Spiral, from 07 to 08 o'clock, within 8 inches of joint: YES221.6 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR230 ft. MWL - Water Level, 20 %of cross sectional area230.4 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR250.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"254.4 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR299 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"299.7 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start359 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN374.8 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Finish375 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish375 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish377.2 ft. AMH - Downstream Manhole, Survey Ends - 08 0679

Observation photos (8)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 09 to 10 o'clock, within 8 inches of joint: YESR

    197 ft. - Roots Fine Joint, from 09 to 10 o'clock, within 8 inches of joint: YESR

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    212 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 07 to 08 o'clock, within 8 inches of joint: YES

    221.6 ft. - Crack Spiral, from 07 to 08 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR

    221.6 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR

    230.4 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR

    254.4 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start

    299.7 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start

Observations (26)

DistanceCodeObservation
374.8RFJ
49.4TFA
194CM
0AMH08 0079
197RFJ
2CM
250.2TFC
377.2AMH08 0679
100.4TFC
201.7TFC
2DAGS
221.6CS
149.9TFOPEN
212CM
299.7RFJ
0MWM
230MWL
0MWL
375DAGS
2SSS
230.4RFJ
299TFC
375SSS
254.4RFJ
221.6RFJ
359TFOPEN

Properties (7)

additional_info
630098012422201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-01-25T02:44:38-08:00
documentation
PRO PIPE
is_lateral_inspection
false