Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 25, 2022, 09:57 AM
  • 08 0081_08 0080_01252022_021709.mp4

Date
01/25/2022
W/O
931501
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00016
PipeID
P00109
Time
1:57 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9712
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
RFIR_WO_931501_TV08116_JAN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
12 in.
Upstream MH
08 0080
Downstream MH
08 0081
Dir. of Survey
Upstream
Length Surveyed
412.3 ft.
Total Length
412.3 ft.
Structural Index
2
Structural Quick
3H2P
Structural Rating
300
O&M Index
2
O&M Quick
2O00
O&M Rating
164
Overall Index
2
Overall Quick
Overall Rating
464
Pipe schematic from manhole 08 0080 to 08 0081
MH: 08 0080MH: 08 0081upstream0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/OPEN0 ft. AMH - Upstream Manhole, Survey Ends - 08 00811.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish2.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish14.4 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"60.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"111.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN161.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"212.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"261.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - OPEN291.2 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES313.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"349.9 ft. CS - Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES362.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"410.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start410.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start410.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start412.3 ft. AMH - Downstream Manhole, Survey Begins - 08 0080412.3 ft. MWM - Water Mark, 15 %of cross sectional area412.3 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES

    62.4 ft. - Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    121.1 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

Observations (21)

DistanceCodeObservation
300.5TFOPEN
2DAGS
49.9TFC
397.9TFC
2SSS
410.7CM
199.5TFC
352TFC
98.9TFC
0AMH08 0080
412.3MGOCONN @ MH 9 O'CLOCK/OPEN
251.2TFC
0MWM
2CM
62.4CS
410DAGS
121.1CL
150.4TFOPEN
410SSS
412.3AMH08 0081
0MWL

Properties (7)

additional_info
630098012422201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-01-25T01:57:36-08:00
documentation
PRO PIPE
is_lateral_inspection
false