Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 26, 2022, 10:20 AM
  • 08 0078_08 0077_01262022_024118.mp4

Date
01/26/2022
W/O
931501
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00016
PipeID
P00080
Time
2:20 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9714
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
RFIR_WO_931501_TV08116_JAN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
15 in.
Upstream MH
08 0077
Downstream MH
08 0078
Dir. of Survey
Upstream
Length Surveyed
359.5 ft.
Total Length
359.5 ft.
Structural Index
2
Structural Quick
413M
Structural Rating
369
O&M Index
2
O&M Quick
2M00
O&M Rating
142
Overall Index
2
Overall Quick
Overall Rating
511
Pipe schematic from manhole 08 0077 to 08 0078
MH: 08 0077MH: 08 0078upstream0 ft. AMH - Upstream Manhole, Survey Ends - 08 00780 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/UNKNOWN0.1 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0.5 ft. MGO - General Observation - ROACHES @ MH2.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish2.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish66.7 ft. H - Hole, from 02 to 03 o'clock, within 8 inches of joint: YES66.8 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: NO120.8 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"143.8 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES156.1 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES171.9 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"197.3 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES219.8 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"242.9 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES270 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"324.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"357.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start357.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start357.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start359.5 ft. AMH - Downstream Manhole, Survey Begins - 08 0077359.5 ft. MWM - Water Mark, 20 %of cross sectional area359.5 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE359.5 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (7)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    116.6 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    162.2 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    203.4 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    215.7 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: NO

    292.7 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: NO

  • Hole, from 02 to 03 o'clock, within 8 inches of joint: YES

    292.8 ft. - Hole, from 02 to 03 o'clock, within 8 inches of joint: YES

Observations (25)

DistanceCodeObservation
2CM
359.5AMH08 0078
139.7TFC
162.2CL
0AMH08 0077
89.5TFC
116.6CL
0MWM
2SSS
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
238.7TFC
203.4CL
359.4MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MWL
187.6TFC
357DAGS
357SSS
359.5MGOCONN @ MH 9 O'CLOCK/UNKNOWN
35.4TFC
357CM
359MGOROACHES @ MH
2DAGS
215.7CL
292.7CL
292.8H

Properties (7)

additional_info
630074012522201
custom_field_three
HOLE IN PIPE
custom_field_two
2
customer
1
datetime
2022-01-26T02:20:15-08:00
documentation
PRO PIPE
is_lateral_inspection
false