Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 2, 2022, 05:55 AM
  • 08 0070_08 0069_02012022_221008.mp4

Date
02/01/2022
W/O
931501
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00016
PipeID
P00072
Time
9:55 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9722
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
02
Purpose
Routine Assessment
Project
RFIR_WO_931501_TV08116_JAN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
08 0070
Downstream MH
08 0069
Dir. of Survey
Downstream
Length Surveyed
301.6 ft.
Total Length
301.6 ft.
Structural Index
2
Structural Quick
322K
Structural Rating
124
O&M Index
2
O&M Quick
2K12
O&M Rating
120
Overall Index
2
Overall Quick
Overall Rating
244
Pipe schematic from manhole 08 0070 to 08 0069
MH: 08 0070MH: 08 0069downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 00700 ft. MWL - Water Level, 20 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start4.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start32.6 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"84.4 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN138.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"189.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"244.1 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN260.4 ft. RFJ - Roots Fine Joint, from 12 to 03 o'clock, within 8 inches of joint: YES266.2 ft. RFJ - Roots Fine Joint, from 10 to 11 o'clock, within 8 inches of joint: YES299 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish299 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish301 ft. MGO - General Observation - ROACHES @ MH301.6 ft. AMH - Downstream Manhole, Survey Ends - 08 0069301.6 ft. MGO - General Observation - SHELF ERRODING301.6 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/CAPPED301.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish301.6 ft. MGO - General Observation - CONN @ MH 9 OC'LOCK/ACTIVE

Observation photos (4)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 12 to 03 o'clock, within 8 inches of joint: YES

    260.4 ft. - Roots Fine Joint, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 10 to 11 o'clock, within 8 inches of joint: YES

    266.2 ft. - Roots Fine Joint, from 10 to 11 o'clock, within 8 inches of joint: YES

  • General Observation - SHELF ERRODING

    301.6 ft. - General Observation - SHELF ERRODING

Observations (21)

DistanceCodeObservation
138.5TFC
244.1TFOPEN
299DAGS
84.4TFOPEN
299SSS
0MWM
2SSS
32.6TFC
301.6AMH08 0069
301.6MGOSHELF ERRODING
301.6MGOCONN @ MH 3 O'CLOCK/CAPPED
2DAGS
301.6CM
301.6MGOCONN @ MH 9 OC'LOCK/ACTIVE
301MGOROACHES @ MH
260.4RFJ
266.2RFJ
189.5TFC
0AMH08 0070
4.2CM
0MWL

Properties (7)

additional_info
630074020122201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-02-01T21:55:57-08:00
documentation
PRO PIPE
is_lateral_inspection
false