Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 26, 2022, 06:10 AM
  • 08 0093_08 0092_01252022_223526.mp4

Date
01/25/2022
W/O
931501
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00016
PipeID
P00121
Time
10:10 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9714
Sewer Name
08 MAIN STREET TRUNK
City
WILLOWBROOK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_931501_TV08116_JAN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
10 in.
Upstream MH
08 0092
Downstream MH
08 0093
Dir. of Survey
Upstream
Length Surveyed
320 ft.
Total Length
320 ft.
Structural Index
2
Structural Quick
3G2M
Structural Rating
256
O&M Index
2
O&M Quick
2L00
O&M Rating
130
Overall Index
2
Overall Quick
Overall Rating
386
Pipe schematic from manhole 08 0092 to 08 0093
MH: 08 0092MH: 08 0093upstream0 ft. AMH - Upstream Manhole, Survey Ends - 08 00932 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2 ft. MGO - General Observation - ROACHES @ MH2.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish2.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish71 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 8"171.4 ft. TBC - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"195.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start224 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES239.3 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES240.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES255.4 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES274.5 ft. TBC - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"297 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES318 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start318 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start318 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES320 ft. MWM - Water Mark, 30 %of cross sectional area320 ft. AMH - Downstream Manhole, Survey Begins - 08 0092320 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE320 ft. MWL - Water Level, 25 %of cross sectional area320 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE

Observation photos (11)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    23 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"

    45.5 ft. - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    64.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    79.3 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    80.7 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    96 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    124.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"

    148.6 ft. - Tap Break-In Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"

  • Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 8"

    249 ft. - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 8"

Observations (22)

DistanceCodeObservation
96CL
23CL
0MWM
80.7CL
0AMH08 0092
320AMH08 0093
318SSS
2SSS
45.5TBC
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
249TBA
124.2CM
148.6TBC
0MWL
79.3CL
64.6CL
317.4DAGS
317.4CM
318MGOROACHES @ MH
2DAGS
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
2CM

Properties (7)

additional_info
630074012522201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-01-25T22:10:22-08:00
documentation
PRO PIPE
is_lateral_inspection
false