Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 29, 2022, 10:12 AM
  • 08 0555_08 0554_3292022_034507.mp4

Date
03/29/2022
W/O
0941747
Weather
Heavy Rain
Operator/Surveyor
MARTIN
Sewer ID
Z00015
PipeID
P00141
Time
3:12 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3050
Sewer Name
08 MAIN STREET RELIEF TRUNK
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
07
Purpose
Capital Improvement Program Assesment
Project
20220329MDM_MAIN_STREET_RELIEF_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Upstream MH
08 0555
Downstream MH
08 0554
Dir. of Survey
Downstream
Length Surveyed
463.8 ft.
Total Length
463.8 ft.
Structural Index
2
Structural Quick
2300
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 08 0555 to 08 0554
MH: 08 0555MH: 08 0554downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:25AM0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. MGO - General Observation - MAG COAT 80%2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE23.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE327.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE331.7 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active463 ft. MGO - General Observation - 80% MAG COAT463 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELIN CONCRETE463.8 ft. AMH - Downstream Manhole, Survey Ends - 5:05AM

Observation photos (4)

  • General Observation - MAG COAT 80%

    2 ft. - General Observation - MAG COAT 80%

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

    23.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

    327.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

Observations (11)

DistanceCodeObservation
463MGO80% MAG COAT
331.7TFAActive
0MWM
327.9SSSBLISTERING PEELING CONCRETE
2MGOMAG COAT 80%
0AMH4:25AM
2SSSBLISTERING PEELING CONCRETE
0MWL
23.9SSSPEELING CONCRETE
463SSSBLISTERING PEELIN CONCRETE
463.8AMH5:05AM

Properties (6)

custom_field_three
BLISTERING PEELING CONCRETE UNDER 80% MAG COAT
custom_field_two
3
customer
LACSD
datetime
2022-03-29T03:12:11-07:00
documentation
MARTIN,REVELES,OLIVER 111,IGNACIO
is_lateral_inspection
false