Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 25, 2022, 08:05 AM
  • 18 1122_18 1121_3252022_013420.mp4

Date
03/25/2022
W/O
0941340
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00711
PipeID
P14975
Time
1:05 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3049
Sewer Name
18 STAGE ROAD JUNCTION TRUNK
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
31
Purpose
Capital Improvement Program Assesment
Project
20220325MDM_STAGE_ROAD_JUNCTION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Upstream MH
18 1122
Downstream MH
18 1121
Dir. of Survey
Downstream
Length Surveyed
323.8 ft.
Total Length
323.8 ft.
Structural Index
2
Structural Quick
352C
Structural Rating
55
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
55
Pipe schematic from manhole 18 1122 to 18 1121
MH: 18 1122MH: 18 1121downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:25AM5 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SLGHGT20.7 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - HAIRLINE45.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped66.2 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - H75.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H78.5 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H93.7 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL100.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped114.8 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SL126.7 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL139.2 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H148.1 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H148.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped153.7 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL160.1 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - SL163.6 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES - SL172.6 ft. FC - Fracture Circumferential, from 09 to 04 o'clock, within 8 inches of joint: YES - SL173.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open187.4 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL190.7 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SL194.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped196.4 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - H220.9 ft. FC - Fracture Circumferential, from 10 to 03 o'clock, within 8 inches of joint: YES - SL236.1 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H239 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H243.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open248.3 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SL275.4 ft. FC - Fracture Circumferential, from 11 to 02 o'clock, within 8 inches of joint: YES - H291.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped293.5 ft. FC - Fracture Circumferential, from 11 to 12 o'clock, within 8 inches of joint: YES - H296.3 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL311.7 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL323.8 ft. AMH - Downstream Manhole, Survey Ends - 2:15AM

Observations (36)

DistanceCodeObservation
291.2TFCCapped
126.7FCSL
20.7FCHAIRLINE
275.4FCH
196.4FCH
148.7TFCCapped
153.7FCSL
160.1FCSL
172.6FCSL
114.8FCSL
239FLH
0MWM
139.2FCH
293.5FCH
78.5FCH
0MWL
236.1FLH
194.2TFCCapped
173.3TBOpen
248.3FLSL
66.2FCH
311.7FCSL
100.2TFCCapped
0AMH1:25AM
243.2TFCOpen
148.1FCH
45.6TFCCapped
5FCSLGHGT
75.5FLH
190.7FCSL
296.3FCSL
220.9FCSL
323.8AMH2:15AM
163.6FLSL
187.4FCSL
93.7FCSL

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2022-03-25T01:05:11-07:00
documentation
MARTIN,OLIVER 111
is_lateral_inspection
false