- Date
- 02/08/2022
- W/O
- 936473
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00210
- PipeID
- P01979
- Time
- 12:52 AM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9724
- Sewer Name
- 01 HUNTINGTON PARK TRUNK
- City
- CUDAHY
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 04
- Purpose
- Routine Assessment
- Project
- RFIR_WO_936473_TV01246_FEB2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 24 in.
- Upstream MH
- 01 1127
- Downstream MH
- 01 1126
- Dir. of Survey
- Downstream
- Length Surveyed
- 288.1 ft.
- Total Length
- 288.1 ft.
- Structural Index
- 3
- Structural Quick
- 3G21
- Structural Rating
- 125
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 125
Pipe schematic from manhole 01 1127 to 01 1126 Observation photos (5)

4.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

8.5 ft. - Crack Spiral, from 11 to 12 o'clock, within 8 inches of joint: YES

19.7 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"

26.7 ft. - Crack Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES

95.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start