Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 8, 2022, 06:39 AM
  • 01 1081_01 0943_02072022_225524.mp4

Date
02/07/2022
W/O
936473
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00210
PipeID
P01930
Time
10:39 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9724
Sewer Name
01 HUNTINGTON PARK TRUNK
City
CUDAHY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_936473_TV01246_FEB2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
01 1081
Downstream MH
01 0943
Dir. of Survey
Downstream
Length Surveyed
378.4 ft.
Total Length
378.4 ft.
Structural Index
3
Structural Quick
3M21
Structural Rating
212
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
212
Pipe schematic from manhole 01 1081 to 01 0943
MH: 01 1081MH: 01 0943downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 10813.4 ft. CM - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES13.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start352.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish366.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES369.1 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES377.5 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK378.4 ft. AMH - Downstream Manhole, Survey Ends - 01 0943

Observation photos (4)

  • Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

    3.4 ft. - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    13.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    366.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    369.1 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

Observations (10)

DistanceCodeObservation
13.8CM
0MWL
369.1CL
378.4AMH01 0943
377.5MGOCONNECTION AT THE MH 9 OC'LOCK
0MWM
366.3CM
352.7CM
0AMH01 1081
3.4CM

Properties (7)

additional_info
630074020722201
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-02-07T22:39:11-08:00
documentation
PRO PIPE
is_lateral_inspection
false