Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 4, 2022, 07:46 AM
  • 08 0036_08 0035_02042022_000111.mp4

Date
02/03/2022
W/O
931877
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00016
PipeID
P00038
Time
11:46 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9863
Sewer Name
08 MAIN STREET TRUNK
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_931877_TV08115_JAN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
08 0036
Downstream MH
08 0035
Dir. of Survey
Downstream
Length Surveyed
326.8 ft.
Total Length
326.8 ft.
Structural Index
3
Structural Quick
4232
Structural Rating
22
O&M Index
2
O&M Quick
2V00
O&M Rating
230
Overall Index
2
Overall Quick
Overall Rating
252
Pipe schematic from manhole 08 0036 to 08 0035
MH: 08 0036MH: 08 0035downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MH0 ft. AMH - Upstream Manhole, Survey Begins - 08 00362 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start34.1 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"77 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS84.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"132.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"187.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"189 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES192.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start199 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start199 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish206.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish236 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"277.4 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES278.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"295.8 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES304.1 ft. CS - Crack Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES324.9 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish324.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish326.8 ft. MGO - General Observation - COCKROACHES IN MH326.8 ft. AMH - Downstream Manhole, Survey Ends - 08 0035

Observation photos (9)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    189 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    192.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    199 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    277.4 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    295.8 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES

    304.1 ft. - Crack Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MH

    326.8 ft. - General Observation - COCKROACHES IN MH

Observations (24)

DistanceCodeObservation
295.8CL
324.9DSZ
236TFC
0MWL
34.1TFC
206.7FM
0MWM
77DSZDEBRIS
132.6TFC
326.8MGOCOCKROACHES IN MH
84.3TFC
304.1CS
277.4CL
192.2CM
324.9DAGS
199FM
189CL
2DAGS
187.7TFC
0MGOCOCKROACHES IN MH
326.8AMH08 0035
0AMH08 0036
278.3TFC
199CM

Properties (7)

additional_info
630138020322202
custom_field_three
FRACTURES/CRACKS
custom_field_two
2
customer
1
datetime
2022-02-03T23:46:53-08:00
documentation
PRO PIPE
is_lateral_inspection
false