Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 11, 2022, 10:00 AM
  • 02 0925_02 0924_01112022_020645.mp4

Date
01/11/2022
W/O
926626
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00252
PipeID
P03493
Time
2:00 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9824
Sewer Name
02 DOWNEY-BELLFLOWER DIVERSION TRUNK
City
PICO RIVERA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
25
Purpose
Routine Assessment
Project
WO_926626_TV02053_DEC2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
15 in.
Upstream MH
02 0925
Downstream MH
02 0924
Dir. of Survey
Downstream
Length Surveyed
74.6 ft.
Total Length
74.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 02 0925 to 02 0924
MH: 02 0925MH: 02 0924downstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 09250 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start72.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish74.6 ft. AMH - Downstream Manhole, Survey Ends - 02 0924

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (6)

DistanceCodeObservation
0MWL
0AMH02 0925
74.6AMH02 0924
0MWM
72.2DAGS
2DAGS

Properties (7)

additional_info
630138011022201
custom_field_three
LIGHT GREASE
custom_field_two
4
customer
1
datetime
2022-01-11T02:00:50-08:00
documentation
PRO PIPE
is_lateral_inspection
false