Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 8, 2022, 08:50 AM
  • J 0053_J 0052_02082022_010544.mp4

Date
02/08/2022
W/O
932167
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00062
PipeID
P11630
Time
12:50 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9776
Sewer Name
J JOINT OUTFALL J - UNIT 2C
City
LOMITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
32
Purpose
Routine Assessment
Project
RFIR_WO_932167_TV05287_JAN2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
42 in.
Width
42 in.
Upstream MH
J 0053
Downstream MH
J 0052
Dir. of Survey
Downstream
Length Surveyed
321.4 ft.
Total Length
321.4 ft.
Structural Index
3
Structural Quick
513K
Structural Rating
191
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
191
Pipe schematic from manhole J 0053 to J 0052
MH: J 0053MH: J 0052downstream0 ft. MWM - Water Mark, 45 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - J 00539.4 ft. MGO - General Observation - MAG COATING10.6 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start11 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES143.7 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 8"319.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish321.4 ft. AMH - Downstream Manhole, Survey Ends - J 0052

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    10.6 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    11 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (9)

DistanceCodeObservation
9.4MGOMAG COATING
0MWM
11SRV
0MWL
143.7TBA
0AMHJ 0053
321.4AMHJ 0052
319.2SAP
10.6SAP

Properties (7)

additional_info
630098020722201
custom_field_three
REINFORCEMENT VISIBLE, AGGREGATE PROJECTING
custom_field_two
2
customer
1
datetime
2022-02-08T00:50:12-08:00
documentation
PROPIPE
is_lateral_inspection
false