- Date
- 02/07/2022
- W/O
- 932167
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00062
- PipeID
- P11624
- Time
- 9:55 PM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9776
- Sewer Name
- J JOINT OUTFALL J - UNIT 2C
- City
- LOMITA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 32
- Purpose
- Routine Assessment
- Project
- RFIR_WO_932167_TV05287_JAN2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Width
- 8 in.
- Upstream MH
- J 0047
- Downstream MH
- J 0046
- Dir. of Survey
- Downstream
- Length Surveyed
- 22.3 ft.
- Total Length
- 22.3 ft.
- Structural Index
- 3
- Structural Quick
- 4331
- Structural Rating
- 17
- O&M Index
- 2
- O&M Quick
- 3112
- O&M Rating
- 5
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 22
Pipe schematic from manhole J 0047 to J 0046 Observation photos (7)

4.8 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

10.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

15 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

15 ft. - Alignment Down, 5 %, Start

17.1 ft. - Fracture Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES

18.1 ft. - Intruding Sealing Ring, 15 %of cross sectional area, from 10 to 02 o'clock

21.3 ft. - Fracture Spiral, from 01 to 05 o'clock, within 8 inches of joint: NO