Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 3, 2022, 08:22 AM
  • 29 0201_29 0223_02032022_004655.mp4

Date
02/03/2022
W/O
936491
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z01025
PipeID
P24100
Time
12:22 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9860
Sewer Name
29 28TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_936491_TV29101_FEB2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0201
Downstream MH
29 0223
Dir. of Survey
Downstream
Length Surveyed
337.3 ft.
Total Length
337.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 29 0201 to 29 0223
MH: 29 0201MH: 29 0223downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MH0 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 02017 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"9.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"28.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start53.4 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"55.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"106.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"109.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"156.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"159 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"206.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"208.7 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"259 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"261.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"308.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"310.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"336 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish337.3 ft. MGO - General Observation - COCKROACHES IN MH337.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK337.3 ft. AMH - Downstream Manhole, Survey Ends - 29 0223

Observation photos (3)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    28.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MH

    337.3 ft. - General Observation - COCKROACHES IN MH

Observations (23)

DistanceCodeObservation
308.3TFC
9.6TFA
337.3MGOCOCKROACHES IN MH
208.7TFC
159TBA
7TFC
206.5TFC
337.3MGOCONNECTION AT MH 3 O'CLOCK
55.9TFA
106.6TFC
53.4TFC
337.3AMH29 0223
336CM
310.9TFC
0MWL
0MGOCOCKROACHES IN MH
28.1CM
0MWM
0AMH29 0201
259TFC
261.5TFC
109.2TFC
156.4TFC

Properties (7)

additional_info
630138020222202
custom_field_three
MULTIPLE CRACKS
custom_field_two
2
customer
1
datetime
2022-02-03T00:22:47-08:00
documentation
PRO PIPE
is_lateral_inspection
false