Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 24, 2022, 08:45 PM
  • _29 0192_01242022_130523.mp4

Date
01/24/2022
W/O
936491
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01025
PipeID
P24090
Time
12:45 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9582
Sewer Name
29 28TH STREET SEWER
City
SIGNAL HILL
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
02
Purpose
Routine Assessment
Project
RFIR_WO_936491_TV29101_FEB2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0192
Dir. of Survey
Upstream
Length Surveyed
134.9 ft.
Total Length
134.9 ft.
Structural Index
3
Structural Quick
513C
Structural Rating
62
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
62
Pipe schematic from manhole 29 0192 to unknown
MH: 29 0192MH: upstream0 ft. AEP - End of Pipe41.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish52.2 ft. B - Broken, from 11 to 02 o'clock, within 8 inches of joint: YES - PIPE MISSING86.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"89.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES89.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"113.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"123.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"126.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"130.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start134.8 ft. MWM - Water Mark, 5 %of cross sectional area134.9 ft. AMH - Downstream Manhole, Survey Begins - 29 0192134.9 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (4)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    45.4 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Broken, from 11 to 02 o'clock, within 8 inches of joint: YES - PIPE MISSING

    82.7 ft. - Broken, from 11 to 02 o'clock, within 8 inches of joint: YES - PIPE MISSING

  • End of Pipe

    134.9 ft. - End of Pipe

Observations (13)

DistanceCodeObservation
0AMH29 0192
0.1MWM
93.4CM
45.4FL
48.4TFC
82.7BPIPE MISSING
45.1TFC
8.2TFC
4.7CM
11TF
0MWL
21.1TFC
134.9AEP

Properties (7)

additional_info
630098012422062
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-01-24T12:45:11-08:00
documentation
PROPIPE
is_lateral_inspection
false