Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 5, 2022, 11:40 AM
  • 32 1287_32 1001_01052022_045954.mp4

Date
01/05/2022
W/O
931520
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00841
PipeID
P19446
Time
3:40 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9816
Sewer Name
32 SOLEDAD CANYON TRUNK, SECTS 1,2,3,&4
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_931520_TV32053_JAN2022
Sewer Type
Gravity
Material
RGRCP
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
32 1287
Downstream MH
32 1001
Dir. of Survey
Downstream
Length Surveyed
283.3 ft.
Total Length
283.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 32 1287 to 32 1001
MH: 32 1287MH: 32 1001downstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 12870 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 6 O'CLOCK2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock, , within 8 inches of joint: YES, Start114.2 ft. SAV - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start184.2 ft. MWL - Water Level, 60 %of cross sectional area229.9 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"233.6 ft. MWL - Water Level, 75 %of cross sectional area240.2 ft. MGO - General Observation - ABANDONED STRUCTURE283.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock, , within 8 inches of joint: YES, Finish283.3 ft. SAV - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish283.3 ft. MCU - Camera Underwater - AT MOUTH OF PIPE.283.3 ft. AMH - Downstream Manhole, Survey Ends - 32 1001

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 12 to 12 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

    114.2 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

  • General Observation - ABANDONED STRUCTURE

    240.2 ft. - General Observation - ABANDONED STRUCTURE

  • Camera Underwater - AT MOUTH OF PIPE.

    283.3 ft. - Camera Underwater - AT MOUTH OF PIPE.

Observations (13)

DistanceCodeObservation
283.3DAGS
240.2MGOABANDONED STRUCTURE
2DAGS
114.2SAV
283.3SAV
0AMH32 1287
283.3MCUAT MOUTH OF PIPE.
229.9TBA
0MWL
233.6MWL
0MGOCONNECTION AT MH 6 O'CLOCK
283.3AMH32 1001
184.2MWL

Properties (7)

additional_info
630138010422202
custom_field_three
Visible Aggregate
custom_field_two
3
customer
1
datetime
2022-01-05T03:40:55-08:00
documentation
PRO PIPE
is_lateral_inspection
false