Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 11, 2022, 12:44 PM
  • 18 0036_18 0453_3112022_044550.mp4

Date
03/11/2022
W/O
0931911
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00691
PipeID
P14305
Time
4:44 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3032
Sewer Name
18 NORTH PLANT OUTFALL TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Capital Improvement Program Assesment
Project
20220310MDM_NORTH_PLANT_OUTFALL_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
18 0036
Downstream MH
18 0453
Dir. of Survey
Downstream
Length Surveyed
12.9 ft.
Total Length
12.9 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 18 0036 to 18 0453
MH: 18 0036MH: 18 0453downstream0 ft. AMH - Upstream Manhole, Survey Begins - 4:45AM0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. MGO - General Observation - ZOOM 10'6 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SLIGHT12.9 ft. AMH - Downstream Manhole, Survey Ends - 4:55AM

Observation photos (1)

  • Downstream Manhole, Survey Ends - 4:55AM

    12.9 ft. - Downstream Manhole, Survey Ends - 4:55AM

Observations (7)

DistanceCodeObservation
0AMH4:45AM
6FCSLIGHT
0MGOConn. @ Mh, 3 O' Clock. Active
2MGOZOOM 10'
12.9AMH4:55AM
0MWM
0MWL

Properties (6)

custom_field_three
SLIGHT FRACTURE
custom_field_two
3
customer
LACSD
datetime
2022-03-11T04:44:54-08:00
documentation
MARTIN,CASTILLO
is_lateral_inspection
false