- Date
- 02/03/2022
- W/O
- 931515
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z01180
- PipeID
- P01467
- Time
- 3:25 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9861
- Sewer Name
- G JOINT OUTFALL G - UNIT 8
- City
- COMPTON
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 19
- Purpose
- Routine Assessment
- Project
- RFIR_WO_931515_TV01236_JAN2022
- Sewer Type
- Gravity
- Material
- RCP-CTL
- Shape
- Circular
- Height
- 36 in.
- Width
- 18 in.
- Upstream MH
- G 0143
- Downstream MH
- G 0144
- Dir. of Survey
- Upstream
- Length Surveyed
- 2 ft.
- Total Length
- 2 ft.
- Structural Index
- 4
- Structural Quick
- 4100
- Structural Rating
- 4
- O&M Index
- 5
- O&M Quick
- 5100
- O&M Rating
- 5
- Overall Index
- 5
- Overall Quick
- —
- Overall Rating
- 9
Pipe schematic from manhole G 0143 to G 0144 Observation photos (3)

2 ft. - Survey Abandoned - REVERSAL COMPLETE

2 ft. - General Observation - MAG COAT

2 ft. - Missing Brick, from 09 to 03 o'clock - TILE