Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 16, 2022, 09:08 AM
  • 04 0080_04 0079_02162022_012734.mp4

Date
02/16/2022
W/O
936555
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00415
PipeID
P11818
Time
1:08 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9872
Sewer Name
04 SHERMAN TRUNK
City
WEST HOLLYWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 04
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_936555_TV04009_FEB2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
04 0080
Downstream MH
04 0079
Dir. of Survey
Downstream
Length Surveyed
356 ft.
Total Length
356 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
3
O&M Quick
3422
O&M Rating
16
Overall Index
3
Overall Quick
Overall Rating
19
Pipe schematic from manhole 04 0080 to 04 0079
MH: 04 0080MH: 04 0079downstream0 ft. AMH - Upstream Manhole, Survey Begins - 04 00800 ft. MGO - General Observation - COCKROACHES IN MH0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start21.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start33.5 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"36.4 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"74.9 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"74.9 ft. RML - Roots Medium Lateral, from 01 to 04 o'clock, 10 %, within 8 inches of joint: YES77.6 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"77.6 ft. RML - Roots Medium Lateral, from 08 to 11 o'clock, 10 %, within 8 inches of joint: YES101.6 ft. ID - Infiltration Dripper, at 01 o'clock, within 8 inches of joint: YES113.9 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"123.8 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"157.2 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"175.5 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"210.6 ft. RML - Roots Medium Lateral, from 07 to 11 o'clock, 10 %, within 8 inches of joint: YES210.6 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"213.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"255.1 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"262.6 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"298.8 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"301.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"348.2 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"350.5 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"354 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish354 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish354 ft. DAE - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish356 ft. MGO - General Observation - COCKROACHES IN MH356 ft. AMH - Downstream Manhole, Survey Ends - 04 0079

Observation photos (9)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Encrustation, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    21.4 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Medium Lateral, from 01 to 04 o'clock, 10 %, within 8 inches of joint: YES

    74.9 ft. - Roots Medium Lateral, from 01 to 04 o'clock, 10 %, within 8 inches of joint: YES

  • Roots Medium Lateral, from 08 to 11 o'clock, 10 %, within 8 inches of joint: YES

    77.6 ft. - Roots Medium Lateral, from 08 to 11 o'clock, 10 %, within 8 inches of joint: YES

  • Infiltration Dripper, at 01 o'clock, within 8 inches of joint: YES

    101.6 ft. - Infiltration Dripper, at 01 o'clock, within 8 inches of joint: YES

  • Roots Medium Lateral, from 07 to 11 o'clock, 10 %, within 8 inches of joint: YES

    210.6 ft. - Roots Medium Lateral, from 07 to 11 o'clock, 10 %, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MH

    356 ft. - General Observation - COCKROACHES IN MH

Observations (32)

DistanceCodeObservation
0AMH04 0080
2DAGS
350.5TBA
0MGOCOCKROACHES IN MH
77.6TFA
33.5TFA
74.9TFA
74.9RML
113.9TFA
21.4CM
123.8TFA
0MWM
36.4TFA
301.5TFA
213.6TFA
354DAGS
354CM
0MWL
298.8TFA
262.6TFA
101.6ID
356MGOCOCKROACHES IN MH
210.6RML
255.1TFA
2DAE
354DAE
210.6TFA
356AMH04 0079
175.5TFA
157.2TFA
77.6RML
348.2TFA

Properties (7)

additional_info
630138021522201
custom_field_three
MULTIPLE CRACKS/ENCRUSTATION
custom_field_two
2
customer
1
datetime
2022-02-16T01:08:17-08:00
documentation
PRO PIPE
is_lateral_inspection
false