Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 16, 2022, 07:12 AM
  • 04 0068_04 0047_02152022_234419.mp4

Date
02/15/2022
W/O
936555
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00415
PipeID
P11803
Time
11:12 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9872
Sewer Name
04 SHERMAN TRUNK
City
WEST HOLLYWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 04
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_936555_TV04009_FEB2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
04 0068
Downstream MH
04 0047
Dir. of Survey
Downstream
Length Surveyed
328.1 ft.
Total Length
328.1 ft.
Structural Index
3
Structural Quick
463G
Structural Rating
141
O&M Index
2
O&M Quick
322H
O&M Rating
96
Overall Index
3
Overall Quick
Overall Rating
237
Pipe schematic from manhole 04 0068 to 04 0047
MH: 04 0068MH: 04 0047downstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 04 00680 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MH0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start20.3 ft. H - Hole, at 01 o'clock, within 8 inches of joint: NO21.6 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"31.9 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"31.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish59.2 ft. RMJ - Roots Medium Joint, from 08 to 03 o'clock, 10 %, within 8 inches of joint: YESR62.5 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"85.2 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"102.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"102.1 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS133.3 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"134.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start140.8 ft. DSC - Deposits Settled Compacted, 15 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: YES181.5 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: NO, 6"197.5 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"208.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"261.6 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"326.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish326.1 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish328.1 ft. MGO - General Observation - COCKROACHES IN MH328.1 ft. AMH - Downstream Manhole, Survey Ends - 04 0047, RUN LIST STATES MH AT 295'.328.1 ft. MGO - General Observation - CONNECTION AT MH 9 AND 12 O'CLOCK328.1 ft. MGO - General Observation - MOBILE MMS FOOTAGE - 327'.

Observation photos (7)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Hole, at 01 o'clock, within 8 inches of joint: NO

    20.3 ft. - Hole, at 01 o'clock, within 8 inches of joint: NO

  • Roots Medium Joint, from 08 to 03 o'clock, 10 %, within 8 inches of joint: YESR

    59.2 ft. - Roots Medium Joint, from 08 to 03 o'clock, 10 %, within 8 inches of joint: YESR

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    134.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Settled Compacted,  15 %of cross sectional area, from 07 to 09 o'clock,  , within 8 inches of joint: YES

    140.8 ft. - Deposits Settled Compacted, 15 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MH

    328.1 ft. - General Observation - COCKROACHES IN MH

Observations (28)

DistanceCodeObservation
181.5TFC
328.1MGOCOCKROACHES IN MH
59.2RMJ
102.1TFC
326.1CM
0MGOCONNECTION AT MH 9 O'CLOCK
134.1CM
2FM
208.7TFC
62.5TF
31.9TBA
328.1AMH04 0047, RUN LIST STATES MH AT 295'.
326.1DSZ
0AMH04 0068
261.6TF
140.8DSC
133.3TBA
0MWM
0MGOCOCKROACHES IN MH
21.6TF
31.9FM
20.3H
0MWL
328.1MGOCONNECTION AT MH 9 AND 12 O'CLOCK
85.2TFC
197.5TBA
328.1MGOMOBILE MMS FOOTAGE - 327'.
102.1DSZDEBRIS

Properties (7)

additional_info
630138021522201
custom_field_three
HOLE/FRACTURES/CRACKS
custom_field_two
1
customer
1
datetime
2022-02-15T23:12:34-08:00
documentation
PRO PIPE
is_lateral_inspection
false