05 0641_05 0640_02012022_224500.mp4
21.8 ft. - Water Level, Sag in pipe, 15 %of cross sectional area, Start
23.6 ft. - Fracture Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Start
23.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start
64.5 ft. - Crack Spiral, from 11 to 01 o'clock, within 8 inches of joint: YES, Start
86.1 ft. - Water Level, Sag in pipe, 15 %of cross sectional area, Start
147 ft. - Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES
153 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES
173.6 ft. - Water Level, Sag in pipe, 20 %of cross sectional area, Start
205 ft. - Crack Spiral, from 11 to 12 o'clock, within 8 inches of joint: YES
241.5 ft. - Crack Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 259.3 | MGO | CONNECTIONS IN MH AT BOTH 3 AND 9 O' CLOCK |
| 57.1 | TFC | — |
| 105.9 | TFC | — |
| 256.4 | DAGS | — |
| 205 | CS | — |
| 0 | MWL | — |
| 16.7 | TFC | — |
| 256.3 | MWLS | — |
| 259.3 | AMH | 05 0640 |
| 230.8 | TFC | — |
| 147 | CM | — |
| 173.6 | MWLS | — |
| 57.1 | FS | — |
| 3.5 | MGO | STAINING |
| 13.7 | TFC | — |
| 0 | AMH | 05 0641 |
| 166.6 | TFC | — |
| 121.4 | MWLS | — |
| 64.5 | CS | — |
| 57.1 | MWLS | — |
| 153 | CL | — |
| 23.6 | FS | — |
| 86.1 | MWLS | — |
| 21.8 | MWLS | — |
| 108.8 | TFC | — |
| 233.6 | TFC | — |
| 241.5 | CS | — |
| 60.2 | TFC | — |
| 23.6 | DAGS | — |
| 0 | MWM | — |
| 8.3 | TB | — |
| 169.5 | TFC | — |
| 81.2 | CS | — |