- Date
- 02/10/2022
- W/O
- 936247
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00070
- PipeID
- P11724
- Time
- 2:40 AM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9732
- Sewer Name
- J JOINT OUTFALL J - UNIT 5C
- City
- TORRANCE
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 30
- Page No.
- 07
- Purpose
- Routine Assessment
- Project
- RFIR_WO_936247_TV30075_FEB2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Width
- 8 in.
- Upstream MH
- J 0354
- Downstream MH
- J 0355
- Dir. of Survey
- Upstream
- Length Surveyed
- 110.9 ft.
- Total Length
- 110.9 ft.
- Structural Index
- 2
- Structural Quick
- 3C2D
- Structural Rating
- 103
- O&M Index
- 2
- O&M Quick
- 2C11
- O&M Rating
- 45
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 148
Pipe schematic from manhole J 0354 to J 0355 Observation photos (5)

2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

4.1 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

7.1 ft. - Crack Spiral, from 07 to 09 o'clock, within 8 inches of joint: YES

61 ft. - Roots Fine Joint, at 09 o'clock, within 8 inches of joint: YES

110.5 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES