Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 14, 2021, 12:00 PM
  • P12949_15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5_15 0749_15 0748_POST_SI_Memo.mpg

Date
09/14/2021
W/O
Weather
Dry
Operator/Surveyor
O.QUEZADA
Sewer ID
Z00593
PipeID
P12949
Time
5:00 AM
Certificate
1234
System Owner
1
Date Cleaned
Pre-Cleaning
Jetting
Media Label
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
09
Purpose
POST
Project
ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Sewer Type
Gravity
Material
NRCP
Lining Method
Cured in Place
Shape
Circular
Height
15 in.
Upstream MH
15 0749
Downstream MH
15 0748
Dir. of Survey
Downstream
Length Surveyed
317.7 ft.
Total Length
317.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0749 to 15 0748
MH: 15 0749MH: 15 0748downstream0 ft. AMH - Upstream Manhole, Survey Begins - POST VIDEO21 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"67 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"97.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"113.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"159.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"204.6 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"219.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"317.7 ft. AMH - Downstream Manhole, Survey Ends - POST VIDEO

Observations (9)

DistanceCodeObservation
204.6TBA
97.8TFA
113.2TFA
219.7TFA
159.2TFA
0AMHPOST VIDEO
67TFA
317.7AMHPOST VIDEO
21TFA

Properties (3)

customer
1
datetime
2021-09-14T05:00:00-07:00
is_lateral_inspection
false